Leave Your Message

Multi-joint Isokinetic Training System from China Suppliers - High-Performance Factory Equipment for Muscle Strength Assessment

,

The A8-3 Multi-joint Isokinetic Training and Testing System is the industry benchmark for evaluating and training muscle strength. Recognized as the gold standard, it utilizes cutting-edge Nuclear Magnetic Resonance (NMR) technology for accurate strength assessments. Perfect for fitness professionals and rehabilitation centers, this system sets a new standard in isokinetic training.

,

Product Model and Specifications:
, • Model: A8-3
, • Training Joints: Shoulder, Elbow, Wrist, Hip, Knee, Ankle
, • Dimensions: 200*80*180 cm
, • Training Modes: 22
, • Swivel Angle: -90 to 90 degrees
, • Minimum Speed: 0.02 degrees/second
, • Maximum Torque: 700 Nm
, • Operating Temperature: 5 to 40°C
, • Control: Laptop computer

,

As a leading manufacturer in China, we take pride in being top suppliers of high-quality fitness equipment. Our state-of-the-art factory ensures that every unit meets rigorous industry standards, making the A8-3 an invaluable addition to any training program.

,

    Product Introduction

    The multi-joint isokinetic training and testing system A8-3 is designed for the evaluation and training of isokinetic, isotonic, isometric, centrifugal, centritic, continuous passive and other related items of the six joints of the human shoulder, elbow, wrist, knee, ankle, trunk and neck. It is suitable for neurology, neurosurgery, orthopedics, sports medicine, rehabilitation medicine and other departments. After testing, training, training, all can see testing or training data, the generated data and graphs can be printed into report, can assess the human body function ability, researchers can also be used as research tools. Such as cooperate with innovative design of the waist and neck parts using accessories, can complete cervical flexor group and torso core muscle group of quantitative evaluation of mechanical properties index and cervical or lumbar dorsal flexor group of targeted training. A variety of patterns can be used been at various stages, the biggest range of rehabilitation for the achievement of the joints and muscles.
    Isokinetic muscle testing was conducted in physical constant movement, by measuring the series reflect muscle load parameters, to assess the function of the muscle. The method is objective, accurate, simple, safe and reliable. Human body itself unable to produce uniform movement, must fix the body of the instrument lever, when its voluntary movement, the instrument of speed limiter can according to the size of the body force, at any time to adjust lever of body resistance, to keep the rate of movement of the body to maintain a constant value. Therefore, physical strength, the greater the leverage, the greater the resistance, the greater the load of the muscle is strong, and vice versa. At this time, if a series of parameters reflecting muscle load are measured, the functional state of the muscle can be evaluated.

    Product Features

    Sophisticated rehabilitation evaluation and training system, including a variety of resistance modes. It can be used to evaluate and train 22 movement patterns of six joints of shoulder, elbow, wrist, hip, knee and ankle.

    Can evaluate a variety of parameters, such as peak torque, peak torque to weight ratio, work, etc.

    Low can record, analysis and comparison test results, set specific rehabilitation training plan and target, and record improvement.

    The test and training situation can be viewed during and after the test and training. The generated data and graphs can be printed into reports, which can be used to evaluate the functional ability of the human body, and can also be used as a scientific research tool for researchers.

    Low multiple model applicable been at various stages, the biggest scope realize the recovery of the joints and muscles.

    Strong target, can be tested or trained for specific muscle groups.

    Optional Accessories

    A8C

    Clinical Application

    It is suitable for muscle apraxia atrophy caused by decreased movement or other reasons, muscle atrophy caused by muscle lesions, muscle dysfunction caused by neuropathy, weakened muscle strength caused by joint diseases or injuries, muscle dysfunction, and muscle strength training for healthy people or athletes.

    Indications

    Musculoskeletal system injury

    Suitable for knee arthritis, anterior and posterior cruciate ligament injury, meniscus injury, total joint replacement, fracture surgery, muscle strain, tendon reconstruction surgery, etc.

    Nervous system injury

    For stroke, spinal cord injury, brain injury, Parkinson's disease, multiple sclerosis, Guillain-Barre, neuromyelitis optica and other nerve injury caused by motor and sensory dysfunction.

    Low on cardiopulmonary function

    Suitable for heart, heart bypass surgery, heart function after stent, reduced lung function, etc.

    Low common chronic diseases

    Suitable for chronic obstructive pulmonary disease (COPD), high blood pressure, high cholesterol, diabetes, kidney disease syndrome.

    Want to know more, many joint isokinetic training and testing system? (Video or color page)

    Frequently Asked Questions

    What is the primary function of the A8-3 isokinetic training and testing system?

    The A8-3 system is designed to evaluate and train isokinetic, isotonic, isometric, centrifugal, centritic, and continuous passive movement of six major human joints: shoulder, elbow, wrist, knee, ankle, trunk, and neck.

    Which clinical departments can benefit from using the A8-3 system?

    It is highly suitable for neurology, neurosurgery, orthopedics, sports medicine, rehabilitation medicine, and other related clinical departments.

    What parameters does the isokinetic system measure to evaluate muscle function?

    The system measures and evaluates multiple parameters, including peak torque, peak torque to weight ratio, work, and various other parameters reflecting muscle load.

    Is the isokinetic muscle testing method safe and reliable?

    Yes, the method is objective, accurate, simple, safe, and reliable. By fixing the body to the instrument lever, the speed limiter adjusts the resistance in real-time according to the force applied, keeping the movement speed constant.

    What types of musculoskeletal injuries are indicated for this training?

    It is indicated for knee arthritis, anterior and posterior cruciate ligament injury, meniscus injury, total joint replacement, fracture surgery, muscle strain, and tendon reconstruction surgery.